Published in final edited form as: Dent Mater. 2014 Mar 25;30(5):545–553. doi: 10.1016/j.dental.2014.02.011

Table 2.

Edge chip results

Material Test piece IndenterX N XX Edge Toughness Te, slope of linear eq.1 (N/mm) Edge strength SE(0.5) (N) calculated* Hardness (GPa)

PMMA
SR Vivodent Plus DCL
Wear block 120° SC 18 475 (44) 238 0.337 (0.014)
Knoop 32 642 (108) 321 0.225 (0.005)
Rockwell C 7 (535 ) - 0.326 (0.007)

Mounted and flattened teeth 120° SC 13 500 (120) 250 -

Combined wear block and teeth 120° SC 31 486 (51) 243

Composite I
SR Phonares NHC
Wear block 120° SC 25 249 (38) 125 0.459 (0.009)
Vickers 8 (575 ) - -
Knoop 32 554 (63) 277 0.302 (0.025)
Rockwell C 17 412 (35) 206 0.448 (0.009)

Mounted and flattened teeth 120° SC 15 251 (23) 126 -

Combined wear block and teeth 120° SC 40 250 (22) 125

Composite II
SR Phonares II
Wear block-incisal 120° SC 26 470 (83) 235 0.395 (0.007)
Knoop 33 705 (60) 358 0.280 (0.013)
Rockwell C 16 587 (99) 294 0.405 (0.006)

Wear block-dentin 120° SC 33 450 (61) 225 0.380 (0.008)
Vickers 9 (1600 ) - -
Knoop 31 596 (55) 298 0.267 (0.018)
Rockwell C 14 490 (69) 245 0.395 (0.001)

Mounted and flattened teeth 120° SC 11 472 (311) 236 -

Combined wear block and teeth 120° SC 70 462 (48) 231 -
Knoop 64 651 (47) 326 -
Rockwell C 30 545 (63) 273 -

Uncertainties, if available, are in parenthesis and are ± one standard deviation

X

SC denotes sharp conical

XX

N is the number of chips

*

eq. 1 with d = 0.5 mm

Data was very inconsistent. Most trials did not result in a chip.