TABLE III.

SNR (mean ± standard deviation) after filter convergence for variable number of data channels, calculated over 50 trials of data with an initial SNR of 0 dB.

Channels ACAR ICA
2 2.4 ± 0.3 1.9 ± 1.1
4 4.7 ± 0.5 3.7 ± 1.3
8 7.2 ± 0.8 4.7 ± 1.1
16 9.2 ± 0.9 5.7 ± 1.0
32 11.6 ± 0.9 6.4 ± 0.8
64 13.8 ± 1.0 7.1 ± 0.5