Table 3.

Dosimetric comparison of photon-based SBRT and proton-based SBRT therapy plans

Characteristic Photon-based SBRT plan Proton-based SBRT plan p Value
median (range) median (range)
PTV
Percentage coverage 96 (95 to 99) 97 (95 to 99)
Chest wall (cm3)
V20 364.0 (240.0 to 511.5) 160.0 (5.0 to 253.0) < 0.0001
V30 144.6 (82.3 to 238.5) 77.0 (30.3 to 111.4) 0.0012
V35 93.9 (54.8 to 167.7) 57.9 (21.3 to 93.6) 0.0054
V40 66.5 (36.9 to 123.1) 45.4 (15.1 to 78.5) 0.0112
Lung
Mean dose (Gy) 57.5 (38.0 to 80.2) 38.8 (29.0 to 44.9) 0.0001
V10 (cm3) 17.5 (11.0 to 29.0) 12.7 (9.2 to 16.0) 0.0010