Skip to main content
. Author manuscript; available in PMC: 2014 Jul 8.
Published in final edited form as: IEEE Trans Med Imaging. 2012 Aug 8;31(10):1977–1988. doi: 10.1109/TMI.2012.2212203

TABLE I.

Comparison between the proposed algorithm and the previous algorithm for direct reconstruction.

Prevous Algorithms [13] Proposed Algorithm
Surrogate Function paraboloidal surrgoate EM surrogate
Monotonic Convergence yes yes
Reconstruction Step paraboloidal update EM update
Smoothing Step spatial filtering spatial filtering
Fitting Step least squares fitting by the Levenberg-Marquardt (LM) algorithm penalized likelihood fitting by the modified LM algorithm
Compartment type any types any types
Background Events must be positive no requirement