Skip to main content
. Author manuscript; available in PMC: 2014 Jul 9.
Published in final edited form as: Carbon N Y. 2014 Feb 10;72:215–223. doi: 10.1016/j.carbon.2014.02.005

Table 1.

Measured thermochemical parameters of graphene oxide reduction.

GO film
drop-cast
cycle
number
GO layer
number
(estimated from
GO mass, Eq. 1)
Heating Rate, 10 Kmin−1 Heating Rate, 50 Kmin−1
GO
Mass
[mg]
Tmax

°C
Exothermic
heat
[Jg−1]
Total
Heat
[J]
GO
Mass
[mg]
Tmax

°C
Exothermic
heat
[Jg−1]
Total Heat

[J]
6 3E+4 0.334 202 1568 0.524 0.463 230 1394 0.645
9 6E+4 0.648 200 1659 1.075 0.684 228 1459 0.998
12 9E+4 1.046 202 1639 1.714 1.064 227 1509 1.606
15 1.1E+5 1.242 206 1680 2.087 1.306 227 1457 1.903
GO cake 2.9E+5 3.250 190 1463 4.755 ND