Table 1.
Slopea | Intercepta | AUCb | |
---|---|---|---|
Spectral fitting after background is subtracted | |||
Estimated RIS | 1.59±0.12 | 1.84±0.38 | 0.90±6 |
Actual RIS | 1.42±0.10 | 3.20±0.30 | 0.92±5 |
Spectral fitting with background included followed by post-fitting background correction for RIS | |||
Estimated RIS* | 1.48±0.15 | −0.15±0.48 | 0.83±9 |
Actual RIS* | 1.61±0.16 | 1.11±0.51 | 0.87±7 |
a± 1 SE.
bAUC calculated from the ROC analysis of the estimated and actual RIS values derived from the spectral fitting of clipped nail spectra, without (RIS) or with (RIS*) background included during the spectral fitting. The error values represent 1 SD.