Skip to main content
. 2014 Jul;52(7):2536–2543. doi: 10.1128/JCM.00387-14

TABLE 2.

Sensitivities of different capture ELISAs tested

Capture MAb (isotype) Detection MAb Sensitivity (ng/ml)a
5G2 (IgG1) 4G3 333
4H3 ND
6G1 (IgG1) 4G3 ND
4H3 ND
9H2 (IgG1) 4G3 ND
4H3 ND
10C12 (IgG1) 4G3 0.5
4H3 0.5
4G3 (IgG2b) 10C12 0.5
5G2 37
6G1 ND
9H2 ND
4H3 (IgG2b) 10C12 0.5
5G2 ND
6G1 ND
9H2 ND
a

Sensitivity is defined by the lowest concentration of SEl-K from which the starting concentration (1 μg/ml) could be calculated by using the linear-fit standard curve generated in each ELISA. Antibody combinations without a sensitivity value listed did not successfully bind SEl-K in this assay; hence, calculations were not done (ND).