Skip to main content
. Author manuscript; available in PMC: 2014 Dec 1.
Published in final edited form as: IEEE Trans Ultrason Ferroelectr Freq Control. 2013 Dec;60(12):2471–2487. doi: 10.1109/TUFFC.2013.2847

Table 3.

Number of plaque types and features as determined by the pathologist collapsed according to the dichotomization thresholds (see ‘Statistical Analysis’). Each entry represents the number of image subsections under each rating, with each row totaling 88 (22 arterial FOVs × 4 subsections/FOV), the total number of subsections rated by the pathologist.

Rating Category True Negatives True Positives

Plaque Detection None, Type I - II Type III – V(a/b/c)*

71 17

Collagen No Plaque Present or Decreased Compared to Average Plaque Comparable or Increased Compared to Average Plaque

65 23

IEL Intact Degraded

64 24

Calcium Not Present Present

82 6

Lipid Pool Not Present Present

73 15

Fibrous Cap Not Present Present

73 15
*

The pathologist could rate up to Type VI plaques, but no arteries in this study developed plaques of this type