Table 5.

Summary of parameters, formulae and their descriptions using data extracted from the OJIP test

Fluorescence parameters Fluorescence parameters description
Extracted parameters
 
Ft
Fluorescence intensity at time t after onset of actinic illumination
F50 μs
Minimum reliable recorded fluorescence at 50 μs with the Handy PEA
Fk (F300 μs)
Fluorescence intensity at 300 μs
FP
Maximum recorded (=maximum possible) fluorescence at P-step
Area
Total complementary area between fluorescence induction curve and F = Fm
Derived parameters
 
Fo ≌ F50 μs
Minimum fluorescence, when all PSII RCs are open
Fm = FP
Maximum fluorescence, when all PSII RCs are closed
Vj = (Fj - Fo)/(Fm - Fo)
Relative variable fluorescence at the J-step (2 ms)
Vi = (Fi - Fo)/(Fm - Fo)
Relative variable fluorescence at the I-step (30 ms)
WK = (Fk - Fo)/(Fj - Fo)
Representing the damage to oxygen evolving complex (OEC)
Mo = 4 (Fk - Fo)/(Fm - Fo)
Approximated initial increment (in ms-1) of the relative variable fluorescence
Fv/Fm = 1- (Fo/Fm)
Maximum quantum yield of primary photochemistry at t = 0
φEo = ETo/ABS = (Fm-Fj)/Fm
Quantum yield for electron transport at t = 0
RCQA = φPo × (ABS/CSm) × (Vj/Mo) Amount of active PSII RCs (QA-reducing PSII reaction centers) per CS at t = m