Table 1.

Summary of the performed image acquisition parameters

Device Number of images Resolution [pixel × pixel] Object of imaging Additional comments
NICON E 600 microscope (lens: Plan Fluor 100×/130 Oil, eyepiece 10×/22)
40
1024 × 1024
Determination of the extent of proliferation in the regenerating rat liver cells
The test material was analysed under the microscope
Systems for 3D measurement of points of the human body developed in the Department of Photogrammetry and Computer Remote Sensing WGGiIŚ AGH
800
1200 × 1600
Evaluation of postural defects
Images of selected places of the human body, signalled with Styrofoam balls-markers, were obtained using two focus free compact cameras
OCT SS-1000 CASIA, OCT Zeiss Visante OCT and SOCT Copernicus Optopol Tech. SA
100'000
256 × 1024
Evaluation of retinal layer thickness and the iridocorneal angle of the anterior segment of the eye
The images are acquired for the measuring range of 8 × 16 mm
AGEMA 470 and/or 640 AGEMA digital camera QV - 400
503
140 × 140 320 × 240 600 × 400
Evaluation of uneven temperature distribution around paraspinal areas
Patients prior to the test were stripped to the waist and stayed in a room with air temperature of 21°C, in a sitting position without any back support for about 20 minutes. Next, each of them stood with their back to the camera at a distance of 2 m from the lens
Flir SC5200 infrared camera with a photon detector with 3-5 μm spectral range,
80
320 × 256
Evaluation of the correctness of performing ablative and non-ablative treatments in cosmetology
Forcing thermal changes of the skin was done using CO2RE laser with a wavelength of 10600 nm; pulse mode of the laser beam emission, energy density of 4,5 J/cm2, pulse energy of 1–150 mJ, pulse frequency of 16,7 kHz, spot size - 120 μm or 150 μm.
Topcon 3D OCT-2000
25'200
884 × 512
Evaluation of Thickness loss of tooth enamel
Images were obtained in vitro by performing on 180 teeth 7 processing steps: tooth without interference, polishing with paste, etching, application of adhesive system, orthodontic bracket attachment, orthodontic bracket removal, cleaning of adhesive residue.
Corvis tonometer 13'400 200 × 576 Evaluation of the mechanical properties of the cornea and intraocular pressure Subjects aged 17–63 were healthy (32 people including 16 women) or ill (16 people including 9 women). The ill patients had either AMD or other diseases that cause abnormal pressure in the eye