Table 1.

Subject-specific values of the passive and active material parameters

VA1 VA2 VA3 VA4 VA5 Average SD
C0, kPa 0.117 0.121 0.105 0.107 0.123 0.115 0.00817
B0 12.4 15.0 18.3 16.0 10.1 14.4 3.18
Tmax, kPa 130 149 148 132 155 143 11.1

Parameters were calibrated so as to match end-diastole volumes and pressures and to minimize the distance of the pressure-volume relationship to the Klotz curve (for passive parameters), and so as to match end-systole volumes and pressures (for active parameters). VA1–VA5, subjects 1–5; C0, scaling factor; B0, factor that determines the level of nonlinearity of the stress-strain relationship; Tmax, factor that reflects the overall contractility of the myocardial tissue.