Skip to main content
. 2014 Jul 1;2014:837439. doi: 10.1155/2014/837439

Table 2.

Comparison of the regression lines between quantification methods of measuring DAT availabilities.

Method Slope (P value∗) Intercept Decline per decade (95% CI∗∗) R 2
(1) MRI-delineation −0.015 (5.4 × 10−6) 2.49 6.66% (4.34–8.52%) 0.22
(2) SPECT-delineation −0.013 (1.7 × 10−5) 1.62 9.47% (5.99–14.13%) 0.20
(3) Template-ROI −0.011 (1.3 × 10−5) 1.86 6.81% (4.52–8.77%) 0.25
(4) 90% Threshold-ROI −0.018 (1.7 × 10−4) 3.31 5.95% (3.34–8.10%) 0.16
(5) 85% Threshold-ROI −0.017 (1.5 × 10−4) 3.15 6.09% (3.46–8.29%) 0.16
(6) 80% Threshold-ROI −0.017 (1.4 × 10−4) 2.99 6.19% (3.63–8.45%) 0.16
(7) 75% Threshold-ROI −0.016 (1.3 × 10−4) 2.84 6.29% (3.60–8.63%) 0.16
(8) 70% Threshold-ROI −0.015 (1.0 × 10−4) 2.68 6.47% (3.45–8.73%) 0.17
(9) 65% Threshold-ROI −0.015 (8.7 × 10−5) 2.52 6.64% (3.62–9.10%) 0.17
(10) 60% Threshold-ROI −0.014 (7.9 × 10−5) 2.36 6.88% (3.86–9.42%) 0.17
(11) MRI-normalization −0.018 (5.1 × 10−8) 1.95 11.02% (7.98–13.66%) 0.31
(12) MRI-normalization with VC −0.021 (5.5 × 10−8) 2.24 11.17% (8.12–13.80%) 0.30
(13) MRI-normalization with GTM −0.028 (1.7 × 10−7) 2.89 11.85% (8.45–14.77%) 0.29
(14) MRI-normalization with RBV −0.027 (3.8 × 10−7) 2.80 11.99% (8.45–15.03%) 0.27
(15) SPECT-normalization −0.014 (3.3 × 10−9) 2.01 8.30% (6.15–9.90%) 0.35
(16) SPECT-normalization with VC −0.017 (4.5 × 10−9) 2.35 8.28% (6.18–9.93%) 0.34
(17) SPECT-normalization with GTM −0.021 (1.2 × 10−8) 3.01 7.99% (5.84–9.63%) 0.33
(18) SPECT-normalization with RBV −0.020 (2.0 × 10−8) 2.91 8.04% (5.87–9.71%) 0.32

CI, confidence interval; DAT, dopamine transporter; MRI, magnetic resonance imaging; SPECT, single photon emission-computed tomography; ROI, region of interest; GTM, geometric transfer matrix; RBV, region-based voxel-wise; VC, Van-Cittert deconvolution.

*P-values for H 0: β 1 = 0.

**95% Confidence intervals for declines per decade using 10,000 bootstrap samples.