Accuracy, repeatability and thresholds for hypomobility (HT) and minimal detectable change (MDC) in IV-RoM in healthy volunteers

 
Flexion
Extension
AccuracyRMS error ( o ) repeatability In plane 0.21 intra-observer Out of plane 0.50 inter-observer In plane 0.34 intra-observer Out of plane 0.40 inter-observer
Agreement (SEM)
 
 
 
 
C1-2
0.8
0.8
1.1
0.4
C2-3
0.3
0.4
0.8
0.7
C3-4
0.5
0.3
1.0
1.0
C4-5
0.6
0.5
0.8
0.8
C5-6
0.5
0.3
1.1
1.0
Reliability (ICC, 95% CI)
*
μ
*
μ
C1-2
0.97 (0.89-0.99)
0.96 (0.82-0.99)
0.90 (0.64-0.97)
0.97 (0.88-0.99)
C2-3
0.97 (0.90-0.99)
0.97 (0.90-0.99)
0.95 (0.80-0.99)
0.95 (0.71-0.98)
C3-4
0.99 (0.98-0.99)
0.99 (0.98-0.99)
0.92 (0.71-0.98)
0.97 (0.87-0.99)
C4-5
0.97 (0.89-0.99)
0.97 (0.89-0.99)
0.97 (0.89-0.99)
0.97 (0.85-0.99)
C5-6
0.99 (0.97-0.99)
0.99 (0.97-0.99)
0.97 (0.85-0.99)
0.97 (0.85-0.98)
Thresholds (o)
HT
MDC
HT
MDC
C1-2
1.3
3.8
1.1
4.4
C2-3
0.8
3.0
0.9
4.5
C3-4
1.8
3.9
2.3
6.4
C4-5
2.3
3.4
3.5
4.7
C5-6 1.1 3.4 1.3 5.0

* = ICC(3C,1), μ = ICC (2C,1), two-way single measure mixed effects model (consistency).