Table 2. Best-Fit Equivalent Circuit Parameters (Standard Errors) Following Exposure to Different BDE-47 Concentrations.
BDE-47 concentration (μg/mL) | 0 | 0.01 | 0.03 | 0.05 | 0.07 | 0.1 | 0.15 | 0.2 | 0.3 | 0.4 |
---|---|---|---|---|---|---|---|---|---|---|
Rs (Ω cm2) |
57.07 (0.6) |
56.38 (0.6) |
56.32 (0.6) |
55.99 (0.6) |
55.59 (0.5) |
56.73 (0.6) |
56.67 (0.5) |
55.92 (0.6) |
56.67 (0.6) |
57.16 (0.6) |
CPE-T (μF cm–2 sn-1) |
3.97 (0.04) |
3.97 (0.04) |
3.98 (0.04) |
3.97 (0.04) |
4.02 (0.04) |
3.97 (0.04) |
4.01 (0.04) |
4.05 (0.04) |
4.03 (0.04) |
3.96 (0.04) |
n | 0.96 (0.01) |
0.96 (0.01) |
0.95 (0.01) |
0.96 (0.01) |
0.96 (0.01) |
0.96 (0.01) |
0.95 (0.01) |
0.96 (0.01) |
0.96 (0.01) |
0.96 (0.01) |
Rct (kΩ cm2) |
396 (6) |
449 (8) |
501 (6) |
537 (6) |
568 (7) |
586 (7) |
602 (7) |
613 (6) |
621 (7) |
625 (7) |