Table 2. ABR thresholds.

Average ABR threshold (dB SPL) Controls vs injected
No. of mice tested 8 kHz SEM 16 kHz SEM 24 kHz SEM 32 kHz SEM P values
5 Controls 38.6 0.9 27.2 2.5 28.7 2.9 43.0 2.2 N/A
10 AAV2/1 35.7 1.3 26.2 2.0 27.4 2.6 46.5 2.6 1.000
9 AAV2/2 37.9 3.5 28.2 1.5 24.3 2.2 43.5 6.2 0.995
11 AAV2/8 37.8 1.6 25.7 3.5 28.8 1.7 47.5 1.9 0.999
11 Lentivirus 49.7 2.9 35.1 4.4 37.7 2.8 58.5 2.7 <0.001

Auditory brain-stem response (ABR) thresholds in decibels sound pressure level (dB SPL) with associated standard errors of the mean for each of four pure tone frequencies are shown. Only the lentivirus group shows a statistically significant difference (P < 0.001) from control ABR thresholds.