Skip to main content
. 2014 Jun 5;289(30):20477–20488. doi: 10.1074/jbc.M114.551119

TABLE 2.

Parameters derived from SAXS analysis of IN preparations

Sample Concentrationa Guinier
GNOMc
Molecular mass by I(0)
qRgb Rg I(0) Rg I(0) Dmax
mg/ml Å a.u.d Å a.u. Å Da
INQ 9.2 0.70–1.4 38.7 ± 2.5 0.032 ± 0.002 43.3 0.03 139.5 131,520
6.9 0.68–1.4 41.7 ± 1.6 0.070 ± 0.002 41.9 0.07 125.0 125,253
4.5 0.70–1.4 38.8 ± 1.6 0.017 ± 0.001 39.3 0.02 121.5 115,233
2.3 0.79–1.5 43.3 ± 2.2 0.057 ± 0.003 42.4 0.05 131.5 150,304
INQ + 5 μm GSK1264 2.0 0.40–1.4 38.4 ± 3.6 0.015 ± 0.001 37.2 0.01 114.0 94,200
INQ + 500 μm GSK1264 2.0 0.40–1.4 31.6 ± 2.3 0.013 ± 0.001 35.6 0.01 110.0 108,500
INQ + 5 mm GSK1264 2.0 0.41–1.4 33.3 ± 2.5 0.015 ± 0.001 33.3 0.01 110.0 178,100
INQ + 50 mm GSK1264 2.0 0.53–1.4 79.5 ± 8.1 0.050 ± 0.005 70.4 0.04 222.7 3,316,000
INQ + 500 mm GSK1264 2.0 1.05–2.0 99.6 ± 6.3 0.046 ± 0.005 147.3 0.08 400.0 7,614,000

a As determined by absorbance using a theoretical extinction coefficient.

b Where q = 4πsinθ/λ, where 2θ is the scattering angle, in units of Å−1.

c Ref. 39.

d a.u., arbitrary units.