Table 4. Overall diagnostic values of FDG-PET and WBC/BM imaging in knee prostheses.
FDG-PET imaging | WBC/BM imaging | |
---|---|---|
Sensitivity | 94.7 (18/19) | 33.3 (1/3) |
95% Confidence Interval | 75.4-99.1 | (6.2-79.2) |
Specificity | 88.2 (60/68) | 88.5 (23/26) |
95% Confidence Interval | 78.5-93.9 | (71.0-96.0) |
Positive Predictive Value (PPV) | 69.2 (18/26) | 25.0 (1/4) |
95% Confidence Interval | 50.0-83.5 | (4.6-69.9) |
Negative Predictive Value (NPV) | 98.4 (60/61) | 92.0 (23/25) |
95% Confidence Interval | 91.3-99.7 | (75.0-97.8) |
Accuracy | 89.7 | 82.8 |
95% Confidence Interval | 81.3-91.8 | 76.2-93.5 |
Positive Likelihood Ratio (+LR) | 8.1 | 2.8 |
95% Confidence Interval | 4.4-9.7 | 0.11-15.4 |
Negative Likelihood Ratio (-LR) | 0.06 | 0.7 |
95% Confidence Interval | 0.003-0.29 | 0.15-1.16 |
Area under the ROC curve | 0.915 | 0.609 |
95% Confidence Interval | 0.835-0.964 | 0.411-0.783 |