Table I.

IC50 at which soluble heparin and LMWH inhibit chemokine binding to immobilized heparin.

KC MIP-2 CXCL8
Heparin 0.142 ± 0.0061 2.8 ± 0.45 2.5 ± 0.45
LMWH 3.83 ± 0.9 59.0 ± 9 31.4 ± 0.3
1