Skip to main content
. 2014 Jun 24;14(6):11179–11203. doi: 10.3390/s140611179

Figure 8.

Figure 8.

The control scheme of a convertible frequency air conditioner with Inverter control: different from the fixed frequency air conditioner, convertible frequency one has an electronic expansion valve to adjust a refrigerant flow. Inverter control changes the output continuously with respect to the different refrigerant flow rate. Even though the Inverter control would keep the constant temperature of cooling air flow, it's still a difference causing control.