Skip to main content
. 2014 Jun 13;14(6):10479–10496. doi: 10.3390/s140610479

Table 3.

Sensor readings (average ± standard deviation) at three different CO2 levels. Concentrations obtained by the reference analyzer are also shown. Units are expressed in ppm.

CO2 level 600 2400 4000
Reference 607.9 ± 2.0 2386.5 ± 2.1 4039.4 ± 4.3
Sensor #1 2328.0 ± 2.1 5823.5 ± 4.0 9153.7 ± 6.9
Sensor #2 841.6 ± 2.1 3013.3 ± 4.0 5073.8 ± 6.3
Sensor #3 774.1 ± 2.1 2843.2 ± 4.0 4885.5 ± 6.3
Sensor #4 1976.8 ± 2.1 5133.0 ± 4.0 8280.0 ± 6.3
Sensor #5 943.2 ± 2.1 3150.3 ± 4.0 5339.7 ± 6.3
Sensor #6 743.1 ± 2.1 2751.7 ± 4.0 4762.0 ± 6.3
Sensor #7 866.6 ± 2.1 2992.8 ± 4.0 5111.2 ± 6.3
Sensor #8 828.0 ± 2.1 2951.6 ± 4.0 5079.9 ± 6.3
Sensor #9 978.7 ± 2.1 3164.2 ± 4.0 5274.7 ± 6.3
Sensor #10 1219.9 ± 2.1 3547.7 ± 4.0 5759.0 ± 6.3
Sensor #11 1333.6 ± 2.1 3779.1 ± 4.0 6132.3 ± 6.3
Sensor #12 822.0 ± 2.1 2921.5 ± 4.0 4993.7 ± 6.3