Skip to main content
. 2014 Jul 15;9:156. doi: 10.1186/1748-717X-9-156

Table 2.

Dose-volume constraints for IMRT plans

Structure Type Rank Objective Dose (cGy) Volume (%) Weight
PTV
Target
1
Maximum
5200
0
100
PTV
Target
1
Minimum
4900
100
100
Ipsilateral lung
Organ at risk
2
Maximum
2000
20
100
Ipsilateral lung
Organ at risk
2
Minimum
1200
30
100
Heart
Organ at risk
3
Maximum
4500
0
100
Unspecified tissue Organ at risk 4 Maximum 4500 0 100