Skip to main content
. 2014 Jul 17;2014:892105. doi: 10.1155/2014/892105

Table 4.

Night-time noise exposure levels, dose for churches, and risk of hearing loss in neighbourhoods.

Neighbourhood Location Noise dB(A)∗ Dose (%) 8-hour equivalent noise exposure Risk of noise-induced hearing loss
Source 50 m 100 m source 50 m 100 m
Taboo Line Church of Jesus 80.1 85.3 72.5 10.1% 33.5% 1.8% 75 Minimal
Voice of the Lord Evangelical Church 89 81.5 64.8 78.5% 14.0% 0.3% 83.9 Some
Tribe of Judah Ministries International 101.7 78.5 74.3 1461.7% 7.0% 2.7% 96.6 Significant

Market Square Apostolic Church, Ghana 86.3 80.5 76.5 42.2% 11.1% 4.4% 81.2 Some
Musama Disco Christo Church 100.5 81.3 74.7 1108.8% 13.3% 2.9% 95.4 Significant
St. Peter Methodist Church 83.7 69.7 61.7 23.2% 0.9% 0.1% 78.6 Minimal
Grace Assembly (Assemblies of God) 71.9 78 74.1 1.5% 6.2% 2.5% 66.8 Minimal

Taifa Central Assemblies of God 94.8 74.3 73.9 298.4% 2.7% 2.4% 89.7 Significant
Unique Chapel International 94.7 84.2 67.6 291.6% 26.0% 0.6% 89.6 Significant

Newtown Church of Pentecost 99.5 83.3 70.5 880.7% 21.1% 1.1% 94.4 Significant
Global Evangelical Church 98.5 86.9 70.7 699.6% 48.4% 1.2% 93.4 Significant
Liberty Centre Annex (Assemblies of God) 85.1 74.8 65.3 32.0% 3.0% 0.3% 80 Some

Christian Village Presbyterian Church 82.5 70.8 63.7 17.6% 1.2% 0.2% 77.4 Minimal
Church of Pentecost 97.1 83 72.5 506.8% 19.7% 1.8% 92 Significant
Christ Apostolic Church 94.5 91.4 83.5 278.5% 136.4% 22.1% 89.4 Significant
Evangelistic Fire Ministries International 93.2 82.5 72.7 206.5% 17.6% 1.8% 88.1 Significant

Zongo Laka Grace Chapel International 87.3 72.5 62.5 53.1% 1.8% 0.2% 82.2 Some

Roman Down Church of Pentecost 82.4 64.9 61.6 17.2% 0.3% 0.1% 77.4 Minimal
St. Augustine Catholic Church 80.9 73.9 64 12.2% 2.4% 0.2% 75.8 Minimal
Christ Apostolic Church 100 85.1 73.1 988.2% 32.0% 2.0% 94.9 Significant

Jericho Church of Pentecost 85.7 71.2 63.7 36.7% 1.3% 0.2% 80.6 Some
Church of Christ 82.3 75.2 64.8 16.8% 24.3% 0.3% 77.2 Minimal
Christ Apostolic Church 94.3 83.9 74.4 266% 209% 2.70% 89.2 Significant

Equivalent noise exposure level 98.6 88.2 77.7 7327.8% 633.10% 52.10%

*Measurement time per location is 30 minutes and total exposure time is 11.5 hours for the churches.