Skip to main content
. 2014 Aug;9(4):498–508.

Table 3.

Intra‐rater reliability estimates for range of motion measured across the four measurements at each time point. ICC's were calculated from the repeated measures of ROM that were done consecutively on each subject by the same examiner.

Measurement Time ICC SEM
Extension with IR Pre‐Fatigue 0.98 2.5°
Post Fatigue 0.93 4.4°
24 Hours 0.98 2.5°
48 Hours 0.98 2.5°
SAB Pre‐Fatigue 0.95 2.4°
Post Fatigue 0.96 2.2°
24 Hours 0.92 2.6°
48 Hours 0.95 2.3°
HAD Pre‐Fatigue 0.97 1.7°
Post Fatigue 0.95 1.6°
24 Hours 0.94 1.6°
48 Hours 0.96 1.2°
LF Pre‐Fatigue 0.95 2.1°
Post Fatigue 0.93 2.3°
24 Hours 0.96 2.2°
48 Hours 0.95 2.3°

ICC = Intraclass correlation coefficient; SEM = Standard error of measurement;

SAB = Scapular plane abduction to 60 °, with internal rotation;

HAD = Horizontal adduction; LF = Low flexion, with internal rotation.