Skip to main content
. 2014 Sep 13;372(2024):20130260. doi: 10.1098/rsta.2013.0260

Table 2.

Reference solution of the model compared to values from the literature.

parameter dimension literature note reference solution
XeATM mol 1.537×1013 a 1.5184×1013
(124Xe/130Xe)ATM mol mol−1 0.02337 0.0232
(126Xe/130Xe)ATM 0.0218 0.0217
(128Xe/130Xe)ATM 0.4715 0.470
(129Xe/130Xe)ATM 6.496 6.522
(131Xe/130Xe)ATM 5.213 5.21
(132Xe/130Xe)ATM 6.607 6.60
(134Xe/130Xe)ATM 2.563 2.55
(136Xe/130Xe)ATM 2.176 2.17
129Xe(I)ATM,CORR mol b 3.71×1012
(129Xe(I)/136Xe(Pu))ATM mol mol−1 6.5–7.1 c 6.99
(129Xe(I)/136Xe(Pu))ATM,CORR d 21.75
XeMANT mol 2.0356×1012
(124Xe/130Xe)MANT mol mol−1 0.0293
(126Xe/130Xe)MANT 0.0253
(128Xe/130Xe)MANT 0.508
(129Xe/130Xe)MANT 9.00
(131Xe/130Xe)MANT 5.18
(132Xe/130Xe)MANT 6.73
(134Xe/130Xe)MANT 2.86
(136Xe/130Xe)MANT 2.50

aThe total inventory and isotopic ratios of Xe are from [31].bAmount of 129Xe in the atmosphere coming from the decay of 129I and corrected for loss.cRatio of radioactivity products uncorrected for loss from [64].dRatio corrected for loss.