[Table/Fig-8]:
Object used, type of injury, management and outcome
S. No. | Object used | Dimensions of object | Duration of incarceration | Grade | Removal Technique | Outcome |
---|---|---|---|---|---|---|
1 | Metal Bearing | ID - 3.5cm | 6hrs | Gr.1 | Aspiration tech. with hot compression | Satisfactory |
2 | Metal Nut | UKN | 7days | Gr.3 | Desloughing of gangrenous skin over penis, object removal by string technique (lubricated tape gauze), | Developed skin necrosis and urethral fistula skin grafting done and candidate for urethral reconstructive surgery, but didn’t come for follow up. |
3 | Metal Ring | ID - 2cm | 14hrs | Gr. 2 | Cutting | Satisfactory |
4 | Metal Ring | ID - 2.5cm T - 4mm | 9hrs. | Gr.2 | Cutting | Minor injury to penile skin during removal |
5 | Metal Ring | ID - 2cm T - 8mm | 20hrs | Gr.2 | String Technique (Vicryl No1) with Aspiration | Absconded |
6 | Metal Bearing | ID - 3cm T - 2mm | 18hrs. | Gr.2 | Dorsal slit removal of distal prepuce skin and object re-approximation | Satisfactory |
7 | Metal Nut | ID - 2.5cm T - 1.5cm | 18hrs. | Gr.2 | String Technique (Vicryl No1) with aspiration | Developed skin necrosis, excision of necrotic tissue and reaproximation done later. |
ID – Internal Diameter T – Thickness UKN - Unknown