Table 13.

Analysis of various filter combinations within the LM-LBP filter bank for WCE and colonoscopy

Filter Combination Average Performance for WCE Average Performance for Colonoscopy

P R S A P R S A
36 Gaussian filters + four LBPs 83.9 81.7 95.2 94.8 85.2 96.1 92.9 94.0
18 first-order derivative of Gaussian filters + four LBPs 78.8 80.5 94.4 93.7 85.8 95.7 93.3 94.0
18 second-order derivative of Gaussian filters + four LBPs 74.8 77.4 94.0 93.0 84.9 95.1 92.8 93.5
8 Laplacian of Gaussian filters + four LBPs 69.8 67.7 91.0 90.7 83.6 93.1 92.3 92.6
4 other Gaussian filters + four LBPs 70.2 69.3 91.6 91.1 81.4 92.4 91.1 91.5
All 48 filters + four LBPs 89.0 91.0 97.3 96.9 89.4 98.2 95.1 96.0