Skip to main content
. 2014 Aug 14;10(8):e1003783. doi: 10.1371/journal.pcbi.1003783

Table 1. Parameter values of the stochastic calcium model.

Parameter Description Value/Units
Inline graphic Inline graphic flux coefficient Inline graphic
Inline graphic Inline graphic diffusional flux coefficient Inline graphic
Inline graphic SR leak flux coefficient Inline graphic
Inline graphic maximum capacity of SERCA Inline graphic
Inline graphic SERCA half-maximal activating Inline graphic Inline graphic
Inline graphic Hill coefficient for SERCA 1.75
Inline graphic plasma membrane leak influx Inline graphic
Inline graphic ROCC flux coefficient Inline graphic
Inline graphic maximum capacity of SOCC Inline graphic
Inline graphic SOCC dissociation constant Inline graphic
Inline graphic maximum capacity of plasma pump Inline graphic
Inline graphic half-maximal activating Inline graphic of plasma pump Inline graphic
Inline graphic Hill coefficient for plasma pump 2
Inline graphic the cytoplasmic-to-microdomain volume ratio 100
Inline graphic the cytoplasmic-to-SR volume ratio 10
Inline graphic an instantaneous high Inline graphic at open channel pore when Inline graphic Inline graphic
Inline graphic total number of Inline graphic channels 20