Skip to main content
. 2014 Aug;52(8):2844–2848. doi: 10.1128/JCM.00803-14

TABLE 1.

Analysis of the limit of detection of the ddPCR CMV assay using 2× master mix or 4× master mix compared with the CMV qPCR assay

Dilution (copies/ml) No. of samples No. of positive samples
2× ddPCR 4× ddPCR qPCR
110 8 8 8 8
55 8 8 8 8
27.5 8 7 8 8
13.75 8 6 8 8
6.875 8 3 3 7