Skip to main content
. 2014 Jun 20;307(4):L295–L301. doi: 10.1152/ajplung.00208.2013

Fig. 1.

Fig. 1.

Baseline respiratory system resistance (Rrs; A) and compliance (Crs; B) in 3-wk-old mice exposed to neonatal hyperoxia [40% or 70% oxygen, from birth to postnatal day 7 (P7)] or normoxia (Ctrl). There were statistical differences in baseline Rrs and Crs between both oxygen-exposed groups and controls (*P < 0.05; **P < 0.02).