Skip to main content
. 2014 Aug 18;7(4):697–703. doi: 10.3980/j.issn.2222-3959.2014.04.21

Table 3. Logistic regression analysis showing the image properties of Optomap images [fundus autofluorescence (FAF), lesion touching optic disc, subretinal fluid, green laser separation image, transversal and longitudinal diameter in individual optic disc size] as variables with their contribution to successfully differentiate a melanoma from a nevus.

Variable B S.E. Wald Sig. Exp (B) 95% CI for Exp (B)
Lower Upper
FAF (Median) -0.075 0.031 5.752 0.0016 0.927 0.872 0.986
Lesion touching disc 3.054 1.280 5.691 0.017 21.197 1.724 260.561
Subretinal fluid 19.584 9856.154 0 0.998 3.200E8 0 .
Green laser separation -0.790 0.370 4.548 0.033 0.454 0.220 0.938
Transversal 0.392 0.340 1.330 0.249 1.480 0.760 2.882
Longitudinal 0.416 0.325 1.642 0.200 1.516 0.802 20866

B: B-Coefficient; S.E.: Standard error; Wald: Wald-test; Sig.: Significance; Exp(B): Logistic coefficient; CI: Confidence interval