Skip to main content
. 2014 Aug 7;2014:270137. doi: 10.1155/2014/270137

Table 3.

Summary of literature relating to suture materials in carpal tunnel surgery.

Author Number of patients Materials Outcome
Present study (2013) 53 Vicryl Rapide and Prolene No difference at 2 or 6 weeks comparing VAS, QuickDASH, or Southampton wound score

Erel et al. (2001) [12] 64 Vicryl and Prolene Significantly greater VAS pain scores at 10 days in Vicryl but no difference at 6 weeks including wound healing and complication rates

Theopold et al. (2012) [14] 47 Vicryl Rapide and Novafil No difference in POSAS and numeric scores assessing wound appearance, pain, or satisfaction at 2 and 6 weeks after procedure

Menovsky et al. (2004) [15] 61 Nylon, Vicryl (subcuticular), and stainless steel No differences in pain scores at 2 and 6 weeks. Increased number of complications with Vicryl