Skip to main content
. 2014 Aug 14;7:273–281. doi: 10.2147/MDER.S67784

Table 3.

Accuracy of detection of five auscultatory sounds by three groups of health care personnel

Condition Group
χ2
(P-value)
Trend χ2
(P-value)
Attending physicians
(n=30)
# correct (%)
PG Trainees
(n=105)
# correct (%)
Nurses
(n=117)
# correct (%)
Crackles 29 (96.7) 62 (59.0) 55 (47.0) 24.3 (<0.001) 20.8 (<0.001)
Wheezing 26 (86.7) 84 (80.0) 103 (88.0) 2.85 (0.240) 0.8 (0.377)
Stridor 27 (90.0) 83 (79.0) 72 (61.5) 13.8 (<0.001) 13.5 (<0.001)
Systolic murmur 28 (93.3) 94 (89.5) 76 (65.0) 24.2 (<0.001) 21.0 (<0.001)
Hyperdynamic bowel sounds 10 (33.3) 53 (50.5) 62 (53.0) 3.75 (0.154) 2.67 (0.103)

Abbreviation: PG, postgraduate.