TABLE 1.
Sample | τmeana,b | β1c,d | φ1c,e | β2c,d | φ2c,e | β3c,d | φ3c,e | βlongc,d | φlongc,e |
---|---|---|---|---|---|---|---|---|---|
ns | ns | ns | ns | ns | |||||
TRX1 alone | 1.62 | 0.018 | <0.1 | 0.069 | 1.7 | 0.133 | 10 | ||
TRX1+ASK1-TBD WT | 3.34 | 0.079 | 3.3 | 0.141 | 30 | ||||
TRX1+ASK1-TBD C250S | 4.52 | 0.026 | <0.1 | 0.024 | 1.3 | 0.034 | 3.8 | 0.136 | 38 |
a The mean fluorescence lifetime (τmean) was calculated using Equation 2.
b S.D. = 0.05 ns.
c The fluorescence anisotropies r(t) were analyzed for series of exponentials (Equation 3), where the amplitudes βi represent the distribution of the correlation times φi. Initial anisotropy of Trp31 for all samples is r0 = 0.22 ± 0.01. Amplitudes β1 were calculated as β1 = r0 − (β2+ β3 + βlong) for each sample.
d S.D. = 0.005.
e S.D. = 15%.