Skip to main content
. 2014 Sep;315:67–79. doi: 10.1016/j.heares.2014.07.001

Fig. 10.

Fig. 10

Influence of myelin and active ion channels on the recorded signal. A and B: Recorded responses of a type I cell with unmyelinated peripheral axon, simulated as in Fig. 7. Position of the recording electrode as in Fig. 2C with electrode distance zel = 2 mm (A). Increase of electrode distance to zel = 8 mm causes a smoothed signal of smaller amplitude (B). C and D: Comparison of the early part of the simulated ABR signal for active soma membrane (black) and passive soma membrane (gray).