Skip to main content
. 2014 Aug 18;29:e2014006. doi: 10.5620/eht.2014.29.e2014006

Table 4.

Association between noise level of room in internal medicine department and sleep disturbance of hospitalized patients

Noise in rooms PSQI score
Unadjusted
Adjusteda
β SE 95% CI β SE 95% CI
Equivalent noise level (dBA)
 24 Hours 0.22 0.08 0.07, 0.37* 0.20 0.07 0.05, 0.42*
 Day 0.24 0.09 0.06, 0.42* 0.20 0.09 0.09, 0.53*
 Night 0.13 0.06 0.01, 0.24* 0.12 0.06 0.07, 0.36*
Maximum noise level (dBA)
 24 Hours 0.16 0.07 0.02, 0.30* 0.13 0.07 0.01, 0.32*
 Day 0.13 0.08 -0.02, 0.23 0.10 0.07 -0.01, 0.48
 Night 0.11 0.06 -0.01, 0.24 0.12 0.06 -0.01, 0.21

Sleep disturbance assessed by the Pittsburgh Sleep Quality Index (PSQI).

SE, standard error; CI, confidence interval.

a

Parameter estimated using multiple linear regression model adjusted for age, gender, severity of patients’ disease, medication of sleep interfering drug, and type of room.

*

p<0.05.