Skip to main content
. Author manuscript; available in PMC: 2014 Sep 4.
Published in final edited form as: J Virol Methods. 2009 Jan 6;157(1):98–101. doi: 10.1016/j.jviromet.2008.11.013

Table 1.

Reactivity with seroconversion panels.

Panel ID Luminex assay USDA licensed HIV tests
European test
S/Coa Anti-HIV EIAb
S/Co
HIV Agc
S/Co
PCRd
Copy number
Western blote
Band pattern
3rd Generation EIAf
S/Co
EIAg
S/Co
PRB929 PRB929-01 0.72 0.20 0.50 NEG No Bands 0.20 0.10
PRB929-02 0.81 0.20 0.50 NEG No Bands 0.20 0.20
PRB929-03 1.36 0.20 0.90 POS No Bands 0.30 0.20
PRB929-04 16.02 0.20 13.40 POS No Bands 0.20 0.30
PRB929-05 132.44 0.90 >22.7 POS No Bands 0.70 0.20
PRB929-06 93.94 >16.3 >22.7 POS f24, f160 12.50 2.10
PRB929-07 9.96 >16.3 >22.7 POS 24, 120, 160 >13.0 4.50
PRB950 PRB950-01 0.55 0.20 0.50 BLD No Bands 0.20 1.90
PRB950-02 1.13 0.20 0.70 7×104 No Bands 0.20 2.10
PRB950-03 6.04 0.20 3.30 5×105 No Bands 0.20 2.20
PRB950-04 8.47 >15.5 4.10 5×105 No Bands 16.40 7.00
PRB917 PRB917-01 0.70 0.20 0.40 NEG No Bands 0.10 0.30
PRB917-02 6.19 0.20 3.90 POS No Bands 0.10 0.40
PRB917-03 41.46 0.30 21.60 POS No Bands 0.10 0.40
PRB917-04 h 6.60 12.70 POS No Bands 0.20 1.00
PRB917-05 1.87 10.20 2.40 POS 24.00 7.90 4.50
PRB917-06 1.55 10.80 1.60 POS 24.00 13.60 5.70
PRB917-07 h 9.20 0.40 POS 24, f65, 160 30.40 7.90
a

Data obtained with the Luminex assay expressed as signal/cut-off (S/Co), where cut-off is defined as the mean background value + 3 standard deviations; a S/Co above 1 (in bold) is considered positive.

b

Data provided as S/Co by BBI/SeraCare using the Abbott Anti-HIV 1-2 enzymatic immunoassay.

c

Data provided as S/Co by BBI/SeraCare using the Abbott Anti-HIV1 antigen immunoassay.

d

Data provided as positive or negative values or number of copies per ml of serum using the Roche HIV-1 for panels PRB929 and PRB917 and the Roche amplicor assay for PRB 950.

e

Confirmatory western blots from Ortho/Cambridge, data interpreted using ASTPHLD/CDC criteria (MMWR, vol. 38, S-7, 1989). Faintly stained bands are indiacted by “f”.

f

Data provided as S/Co by BBI/SeraCare using the 3rd generation enzymatic immunoassay fromAbbott 3rd Generation Plus for panels PRB929 and PRB950 and Diagnostic Pasteur HIV 1/2 for panel PRB917.

g

Data provided as S/Co by BBI/SeraCare using the 3rd Generation enzymatic immunoassay from Biotest HIV 1/2 for panels PRB929 and PRB950 and Murex Wellcozyme HIV 1/2 for panel PRB 917.

h

Samples no longer available.