At four weeks, left ventricular function was preserved after EPCM treatment as measured by echocardiography, pressure-volume conductance catheter, and Doppler flow.

Modality Parameter Control (n=22) EPCM (n=21) P Value
Echo LVID systole (mm) 0.67 ± 0.02 0.45 ± 0.02 <0.001
LVID diastole (mm) 0.80 ± 0.02 0.66 ± 0.01 0.001
Infarct Wall Thickness diastole (mm) 1.13 ± 0.11 1.70 ± 0.10 <0.001
Infarct Wall Thickness systole (mm) 1.20 ± 0.12 1.96 ± 0.06 <0.001
Fractional Shortening (%) 16 ± 2 32 ± 1 <0.001
Ejection Fraction (%) 40 ± 4 68 ± 2 <0.001
P-V Conductance Maximum Pressure (mmHg) 95.7 ± 2.5 118.3 ± 5.1 <0.001
dPdt Max (mmHg/sec) 4237 ± 293 5927 ± 388 <0.001
Stroke Work (mmHg*uL) 3998 ± 440 5464 ± 642 0.006
Slope of end systolic pressure-volume relationship 0.75 ± 0.15 2.50 ± 0.05 <0.001
Doppler Flow Cardiac Output (ml/min) 27.3 ± 3.4 39.8 ± 1.1 0.029