Table 1.

Mean values and standard deviations of estimated pulmonary blood flow (PBF), pulmonary blood volume (PBV) and mean transit time (MTT).

Digital lung phantom
PBF
ml blood / 100 ml lung / min
PBV
ml blood / 100ml lung
MTT
s
Ground truth 425.6 ± 85.2 30.6 ± 8.5 4.31 ± 0.19
PCB 470.5 ± 54.0 29.3 ± 5.3 3.73 ± 0.31
PCB+ST 401.6 ± 54.6 28.1 ± 5.7 4.18 ± 0.37
Canine subject
PCB+ST 451.0 ± 154.9 27.2 ± 10.3 3.66 ± 0.89
Human subject
PCB+ST 271.5 ± 104.3 32.7 ± 12.5 7.10 ± 1.43