Table 1.

Cardiac MRI scan parameters.

Echo time (TE), ms Repetition time (TR), ms Flip angle, ° Band width, Hz/pixel Field of view, mm Matrix Spatial resolution, mm2 Slice thickness, mm
Cine MRI True FISP (SSFP) 1.6 25 80 930 300 × 300 156 × 192 1.9 × 1.6 6
T2 weighted MRI T2p-SSFP 1.6 3.2 60 - 90 977 245 × 327 145 × 256 1.7 × 1.3 6
T2* T2* 154 20 977 245 × 327 128 × 256 1.9 × 1.3 4
EGE MRI PSIR-FISP 1.1 557 50 1000 300 × 400 108 × 192 2.8 × 2.1 6
LGE MRI PSIR turbo FLASH 2.53 403 25 201 215 × 300 119 × 256 1.8 × 1.2 6

The T2 preparation time (TE) was 60 ms. Parallel imaging (rate 2) was used and 8 respiratory motion corrected images were obtained per acquisition.

The T2* protocol acquired 16 echoes with echo spacing 2.32 ms, with a minimum echo time of 1.58 ms and a maximum echo time of 36.38 ms (4 phase encodes were acquired per RR with 154 ms imaging duration). The PSIR FLASH had 25 views per segment.

Abbreviations: EGE = early gadolinium enhanced MRI; FISP = fast imaging in steady state precession; LGE = late gadolinium enhanced MRI; MVO = microvascular obstruction; SSFP = steady state free precession; PSIR = segmented phase-sensitive inversion recovery; turbo FLASH = fast low-angle shot.