Skip to main content
. Author manuscript; available in PMC: 2014 Sep 9.
Published in final edited form as: Circ Cardiovasc Imaging. 2011 Sep 19;4(6):738–745. doi: 10.1161/CIRCIMAGING.111.965095

Table 8.

Myocardial hemorrhage according to low signal intensity regions on T2*-weighted MRI in 55 images matched with pathology.

Low signal intensity area No low signal intensity area Adjusted
Hemorrhage (n=37) 35 2 95% (86 - 100%)
sensitivity

No hemorrhage (n=18) 1 17 94% (88 - 100%)
specificity

97%
PPV
90%
NPV
*

Of 80 T2*-weighted MRI acquisitions, 55 were of diagnostic quality and 35 were affected by posterior field artefacts. MVO – microvascular obstruction, PPV – positive predictive value, NPV – negative predictive value.