Skip to main content
. Author manuscript; available in PMC: 2014 Sep 9.
Published in final edited form as: Int J Radiat Oncol Biol Phys. 2011 Mar 26;82(2):708–714. doi: 10.1016/j.ijrobp.2011.01.035

Table 1.

Heart motion in superoinferior and left–right directions calculated from maximal and minimal intensity projection computed tomography images

Pt. No. SI (mm) LR (mm)
1 7.7 0.0
2 3.5 2.1
3 7.4 3.2
4 6.0 2.1
5 10.9 3.2
6 8.4 3.5
7 10.5 4.6
8 6.0 3.2
9 5.1 3.0
10 5.5 2.2
11 5.7 2.0
12 3.8 0.0
13 6.1 1.8
14 8.4 3.0
15 3.0 3.0
16 4.0 1.6
17 5.5 2.2
18 5.6 3.0
19 7.5 4.0
20 7.0 3.0
Average 6.4 2.5
Maximum 10.9 4.6
Minimum 3.0 0.0
SD 2.1 1.1

Abbreviations: Pt. No. = patient number; SI = superoinferior; LR = left–right; SD = standard deviation.