Table 1.
Exposure conditions and times to rupture for all vessels sonicated in the rupture prediction experiments
Trial | AWG output voltage (mVpp) | Measured acoustic power (W) | Computed focal intensity I SPTP (W/cm 2 ) | Computed peak negative pressure (MPa) | Time to rupture (s) |
---|---|---|---|---|---|
1 |
250 |
20.28 |
15,690 |
10.92 |
29 |
2 |
250 |
20.28 |
15,690 |
10.92 |
133 |
3 |
275 |
26.45 |
20,570 |
11.83 |
27 |
4 |
275 |
26.45 |
20,570 |
11.83 |
25 |
5 |
275 |
26.45 |
20,570 |
11.83 |
NR |
6 |
275 |
26.45 |
20,570 |
11.83 |
NR |
7 |
280 |
26.96 |
20,940 |
11.90 |
NR |
8 |
285 |
27.53 |
21,350 |
11.97 |
14 |
9 |
285 |
27.53 |
21,350 |
11.97 |
32 |
10 |
300 |
28.42 |
21,980 |
12.09 |
55 |
11 |
300 |
28.42 |
21,980 |
12.09 |
41 |
12 |
300 |
28.42 |
21,980 |
12.09 |
60 |
13 |
300 |
28.42 |
21,980 |
12.09 |
19 |
14 |
300 |
28.42 |
21,980 |
12.09 |
133 |
15 |
300 |
28.42 |
21,980 |
12.09 |
35 |
16 |
325 |
32.06 |
24,430 |
12.52 |
55 |
17 |
325 |
32.06 |
24,430 |
12.52 |
67 |
18 | 325 | 32.06 | 24,430 | 12.52 | 42 |
In trials 5–7, NR indicates that no rupture occurred. AWG arbitrary waveform generator.