Skip to main content
. 2014 Jul 15;289(37):25581–25589. doi: 10.1074/jbc.M114.576108

TABLE 1.

Parameters of the Boltzmann fits (Equation 3) in different experimental conditions

IATP/I0 is the ratio between the current measured in the presence of ATP and in cytosolic solutions without ATP. Iunh is the residual current in presence of ATP, V½ is the potential at which half of the current was blocked. Data are presented as mean ± S.D.

Ionic conditions
IATP/I0 at −160 mV Parameters
Location
Cytosolic Vacuolar ATPcyt V½ Iunh
mm % mV %
30 mm Malate 100 mm Malate 0.1 46 ± 1 −131 ± 4 40 ± 7 Fig. 1B
30 mm Malate 100 mm Malate 0.5 17 ± 1 −118 ± 1 16 ± 3 Fig. 1B
30 mm Malate 100 mm Malate 1 10 ± 1 −114 ± 0.8 6 ± 2 Fig. 1B
50 mm Malate 100 mm Malate 1 19 ± 2 −119 ± 4 11 ± 5 Fig. 2B
100 mm Malate 100 mm Malate 1 37 ± 2 −135 ± 2 32 ± 5 Fig. 2B
100 mm Cl 100 mm Cl 1 29 ± 3 −66 ± 1 24 ± 1 Fig. 3B
100 mm Cl 100 mm Malate 1 34 ± 2 −124 ± 1 31 ± 2 Fig. 3B
100 mm Malate 0 mm Malate 1 44 ± 2 −112 ± 4 38 ± 4 Fig. 4B
100 mm Malate 1 mm Malate 1 42 ± 1 −113 ± 2 39 ± 3 Fig. 4B
100 mm Malate 10 mm Malate 1 38 ± 3 −119 ± 3 31 ± 4 Fig. 4B
100 mm Malate 100 mm Cl 1 41 ± 3 −135 ± 13 7 ± 16 Fig. 4B