Skip to main content
. 2014 Jun 9;8(3):034110. doi: 10.1063/1.4883275

FIG. 4.

FIG. 4.

(a) Velocity profile at the flow rate of 0.1 ml/h for RBCs in autologous plasma and a fitting curve obtained by Eq. (4). (b) Relationship between the velocity ratio (η) and blood viscosity (μBlood). Solid line depicts the linear-curve fitting with respect to blood viscosity. R2 values and the corresponding fitting equations are included. Dotted lines indicate 95% confidence intervals.