Skip to main content
. Author manuscript; available in PMC: 2014 Sep 15.
Published in final edited form as: J Comput Neurosci. 2010 Dec 30;31(1):137–158. doi: 10.1007/s10827-010-0304-x

Table 2.

Model parameters constrained by current experimental results

Model parameter Value
Axial resistivity (Ra) 140 Ωcm
SR AMPAR time constant (τ12) 3.3 ms
SR AMPAR peak conductance (gmax) 0.5 nS
SLM AMPAR rising time constant (τ1) 0.4 ms
SLM AMPAR falling time constant (τ2) 4.1 ms
SLM AMPAR peak conductance (gmax) 0.9 nS
NMDAR rising time constant (τ1) 5 ms
NMDAR falling time constant (τ2) 16 ms
SR NMDAR peak conductance (gmax) 0.16 nS
SLM NMDAR peak conductance (gmax) 0.18 nS