Table 2.
No. | Sensing Platform | Target | Detection Limit | Linear Range | [Reference] (year) |
---|---|---|---|---|---|
1 | FRET dsDNA probe | DNase I | 40 unit/L | 40–500 unit/L | [16] |
Exonuclease | 2.0 unit/L | 2.0–400 unit/L | (2013) | ||
2 | Fe3O4@MIP nanoparticle | DNase I | - | - | [17] |
(2013) | |||||
3 | Graphene-based fluorescence assay | DNase I | 1.75 unit/mL | 1.75–70 unit/mL | [19] |
(2012) | |||||
4 | Potentiometric sensing using polycation sensitive membrane electrode | S1 nuclease | 0.32 unit/mL | − | [25] |
DNase I | 0.45 unit/mL | 1–10 unit/mL | (2013) | ||
5 | ds DNA template formation Cu nanoparticle | S1 nuclease | 0.3 unit/mL | 1–50 unit/mL | [26] |
(2013) | |||||
6 | Positively charged QDs-based FRET probe | MNase | 1.6 unit/L | 8–90 unit/L | [27] |
(2013) | |||||
7 | Electrochemical detection using FcODN modified electrode (cytosine oligonucleotide) | RNase A | 10 pg/mL | 1 pg/mL–1 μg/mL | [31] |
(2013) |