(a) Schematic diagram showing the sensing mechanism for untreated (hydrophobic) Parylene C (left) and oxidized Parylene C (right) sensing membranes; (b) Filtered data indicating chemical sensitivity of the sensor at distinct pH values; (c) Hysteresis characteristics (unfiltered data); (d) (Left axis) ID−VGS curves of sensor. (Right axis) Corresponding measured leakage currents; (e) Drift trends of a single sensing site under electrolytes of pH 4, 7 and 10. Markers indicate the experimental data and lines the corresponding fitting (exponential) curves.