The attack and release time for a 2 kHz test signal. The top panel shows a 2 kHz input signal that abruptly decreases from an initial level of 90 dB SPL to 55 dB SPL and then increases again to 90 dB SPL. The lower panel shows the response of a compression hearing aid with an attack time of 3 milliseconds and a release time of 50 milliseconds to the same signal.