Skip to main content
. Author manuscript; available in PMC: 2015 Oct 1.
Published in final edited form as: Anesth Analg. 2014 Oct;119(4):867–874. doi: 10.1213/ANE.0000000000000376

Table 3.

Comparison of mean titration size between types of procedures, in mcg•kg-1•min-1.

Type of Procedure Mean Standard Deviation
Catheterization 2.35 1.79
Craniofacial 1.25 0.76
Spinal 1.12 0.67
Procedure Comparison Difference Between Means 95% Confidence Limits
Catheterization - Craniofacial 1.09** 0.22 1.96
Catheterization - Spinal 1.22** 0.36 2.08
Spinal - Craniofacial −0.13 −0.45 0.19

The 3 types of procedures were compared using ANOVA. The mean titration size in each is shown in the top half of the table. Scheffe's test was used to compare the mean titration size among catheterization, craniofacial, and spinal procedures, shown in the lower half of the table. Asterisks indicate a statistically significant difference in the 2 groups' means, p=0.0023.