Skip to main content
. Author manuscript; available in PMC: 2014 Sep 22.
Published in final edited form as: Cochrane Database Syst Rev. 2010 Jun 16;(6):CD001318. doi: 10.1002/14651858.CD001318.pub2
Methods RCT
Participants 110 women with CIN 3
Interventions Laser conisation
Knife conisation
Outcomes Peri-operative blood loss (insufficient data for analysis)
Primary haemorrhage (bleeding requiring intervention in first 4 days)
Secondary haemorrhage (bleeding after 4th day)
Notes 55 women were randomised to laser conisation, 55 to knife conisation
All procedures performed under general anaesthesia
Blood loss estimated by alkaline haematin extraction from swabs etc
Risk of bias
Item Authors’ judgement Description
Adequate sequence generation? Unclear Not reported
Allocation concealment? Unclear Not reported
Blinding?
All outcomes
Unclear Not reported
Incomplete outcome data addressed?
All outcomes
Yes % of women analysed: 110/110 (100%)
Free of selective reporting? Unclear Insufficient information to permit judgement
Free of other bias? Unclear Insufficient information to assess whether an important risk of bias exists